Customization: | Available |
---|---|
Power Supply: | 220V |
Certification: | CE, TUV, ISO |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Model | ST-60C | ST-90C | ST-120C | ST-160C | ST-200C |
Inner dimension WxHxD(mm) | 600x400x450 | 900x500x600 | 1200x500x1000 | 1600x500x1000 | 2000x600x1500 |
Exterior dimension WxHxD(mm) | 1060x990x650 | 1410x1280x880 | 1900x1400x1300 | 2300x1400x1300 | 2750x1450x1850 |
Installed power | 1.5(kw) | 2.5(kw) | 3.5(kw) | 4.5(kw) | 4.5(kw) |
Brine tank capacity | 15L | 25L | 40L | 40L | 40L |
Number of collectors | 1 | 2 | 2 | 2 | 2 |
Number of spray towers | 1 group | 1 group | 2 groups | 2 groups | 2 groups |
Temperature range | RT+10℃~60℃ | ||||
Humidity range | ≥85% R.H or more (dry and wet bulb comparison table calculation) | ||||
Temp.uniformity | ≤±1℃ | ||||
Temp.fluctuation | ≤±0.5℃ | ||||
Pressure barrel temperature | RT+10℃~80℃ | ||||
Salt Mist Settling Volume | 1~2ml/h.80cm² (collected for at least 16 hours, average value taken) | ||||
Spray pressure | 1.00±0.01kgf/cm² | ||||
PH value (PH) | PH=6.5~7.2(NSS)/PH=3.0~3.3(ACSS,CASS) | ||||
Test time | 1~999(S,M,H)(Adjustable) | ||||
Saline solution concentration | Sodium chloride solution concentration 5% (neutral salt spray) | ||||
Sodium chloride solution 5%+ glacial acetic acid (acetate spray) | |||||
Sodium chloride solution concentration 5% + glacial acetic acid + 0.26g CuCl2/L (copper accelerated salt spray) | |||||
Spray way | Continuous spraying + intermittent spraying |
Heating methods | Direct steam heating method |
Controller | PID control, error ± 0.1 ° |
Standard configuration | 1 round bar, 1 V-shaped sample holder, 2 nozzles, 2 sets of funnels and 2 sets of measuring cylinders |
Safety protection device | Over temperature protection |
Lack of water protection | |
Over current protection | |
Power supply | AC 220V/50HZ |